CONSOLIDATED TILING SERVICES
21 November 2000
Our Ref. EN 13/713
Requested by: Tasco Brick Block & Pavers
On: 21 November 2000
Manufacturer: Tasco Brick Block & Pavers
Product Desc. Tasco Tech-Dry Concrete Masonry Unit
Tasco Tech-Dry Mortar
Product size 110mm x 228mm x 75mm
Sampling details:
Where: Delivered
Date: 21 November 2000
By whom: Tasco
How (methods): N/A
The results reported relate only to the sample(s) tested.
No responsibility is taken for the accuracy of the sampling unless it is done under our own supervision.
The reproduction of this test report is only authorised in the form of a complete photographic facsimile. Our written approval is necessary for any partial reproduction.
SUMMARY OF TESTS PERFORMED:
Test based on AS 3700 1988
Flexural Strength by Bond Wrench Average: 0.449 MPa
Flexural Strength by Bond Wrench Test
TEST BASED ON AS 3700 1988
Samples received 15 November 2000 Test Date 21 November
Flexural Strength
Sample No. Mpa
1. 0.357
2. 0.260
3. 0.589
4. 0.426
5. 0.627
6. 0.371
7. 0.308
8. 0.445
9. 0.430
10. 0.681
Average 0.449
Interpretation of results: The Tasco Tech-Dry Masonry Unit with Tech-Dry Mortar show a close and continuous range for the Flexural Strength test . The average of 0.449 Mpa is considered a high result for masonry products.
Date and Place 21 November 2000, Highett, Vic.
BARRY SCHAFER - APPRAISALS MANAGER